<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Siebel Expert Panel &#187; Server Administration</title>
	<atom:link href="http://www.siebeloracle.com/category/siebel-server-administration/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.siebeloracle.com</link>
	<description>Siebel Support Web For Complete Siebel Reference</description>
	<lastBuildDate>Mon, 16 Jan 2012 17:42:14 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.5</generator>
		<item>
		<title>MainWin Processes In Siebel</title>
		<link>http://www.siebeloracle.com/mainwin-processes-in-siebel/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/mainwin-processes-in-siebel/#comments</comments>
		<pubDate>Mon, 16 Jan 2012 17:42:14 +0000</pubDate>
		<dc:creator>Abhishek</dc:creator>
				<category><![CDATA[Server Administration]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=5796</guid>
		<description><![CDATA[In this article we will learn ,What are MainWin executables and how to start, stop or check status of these processes.&#160;

Main win executables are part of embedded MainSoft MainWin System Core (MSC) components.

Starting with Siebel eBusiness Applications version 7.7, Siebel Systems embedded a newer version of MainSoft Mainwin. Three executables were introduced as a part of a design improvement.
&#216;&#160; regss
&#216;&#160; mwrpcss
&#216;&#160; watchdog



&#160;
regss: regss is the registry service of MainWin. This service is in charge of manipulating the registry file which contains system and application information.
mwrpcss: mwrpcss processes the RPC (Remote ...


Related posts:<ol><li><a href='http://www.siebeloracle.com/hung-processes-in-siebel-servers/' rel='bookmark' title='Permanent Link: HUNG PROCESSES In Siebel Servers'>HUNG PROCESSES In Siebel Servers</a></li>
<li><a href='http://www.siebeloracle.com/siebel-server-component-processes-shells/' rel='bookmark' title='Permanent Link: Siebel Server Component Processes (Shells)'>Siebel Server Component Processes (Shells)</a></li>
<li><a href='http://www.siebeloracle.com/siebel-enterprise-server-an-overview/' rel='bookmark' title='Permanent Link: Siebel Enterprise Server &#8211; An Overview'>Siebel Enterprise Server &#8211; An Overview</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/mainwin-processes-in-siebel/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Graceful Shutdown Of Siebel Server</title>
		<link>http://www.siebeloracle.com/siebel-server-not-shutting-down/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/siebel-server-not-shutting-down/#comments</comments>
		<pubDate>Mon, 12 Sep 2011 11:24:36 +0000</pubDate>
		<dc:creator>Sourav Mukherjee</dc:creator>
				<category><![CDATA[Server Administration]]></category>
		<category><![CDATA[Siebel Tips & Tricks]]></category>
		<category><![CDATA[Siebel Server Administration]]></category>
		<category><![CDATA[User Query And Resolution]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=5240</guid>
		<description><![CDATA[Problem Statement : Siebel servers are not shutting down after executing the stop_server all  command and the error which is frequently observed is “server not shutting down” or “server services could not be shut down”. 


Related posts:<ol><li><a href='http://www.siebeloracle.com/siebel-enterprise-server-an-overview/' rel='bookmark' title='Permanent Link: Siebel Enterprise Server &#8211; An Overview'>Siebel Enterprise Server &#8211; An Overview</a></li>
<li><a href='http://www.siebeloracle.com/how-to-take-clean-bounce-of-siebel-server/' rel='bookmark' title='Permanent Link: How to take Clean Bounce of Siebel Server'>How to take Clean Bounce of Siebel Server</a></li>
<li><a href='http://www.siebeloracle.com/synchronization-of-siebel-server-components/' rel='bookmark' title='Permanent Link: Synchronization Of  Siebel server components'>Synchronization Of  Siebel server components</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/siebel-server-not-shutting-down/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>HUNG PROCESSES In Siebel Servers</title>
		<link>http://www.siebeloracle.com/hung-processes-in-siebel-servers/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/hung-processes-in-siebel-servers/#comments</comments>
		<pubDate>Tue, 16 Aug 2011 07:15:29 +0000</pubDate>
		<dc:creator>Sourav Mukherjee</dc:creator>
				<category><![CDATA[Server Administration]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=5030</guid>
		<description><![CDATA[Health of these siebel server processess play major role to keep the application and other operational functionalities smooth and fine.&#160;&#34;Process&#34; is a collection of many &#34;Tasks&#34; or &#34;Threads&#34;. All these threads are defined within a process, under a specified parameter within the siebel server for different functionalities.
Example: MaxSharedDbConns , MinSharedDbConns, MinMTServers ,MaxMTServers parameters for AOM component &#34;eCommunicationsObjMgr_enu&#34;.

&#160;Thus in case if these Threads/Tasks within a Process gets hanged or show the error such as:


Handling logon
Excited with Error
Running status but for more than 1 to 2 hours or greater.&#160;&#160;

&#160;
&#160;Hint-1: (command to check ...


Related posts:<ol><li><a href='http://www.siebeloracle.com/siebel-architecture-siebel-server/' rel='bookmark' title='Permanent Link: Siebel Architecture and Servers &#8211; An Overview'>Siebel Architecture and Servers &#8211; An Overview</a></li>
<li><a href='http://www.siebeloracle.com/mainwin-processes-in-siebel/' rel='bookmark' title='Permanent Link: MainWin Processes In Siebel'>MainWin Processes In Siebel</a></li>
<li><a href='http://www.siebeloracle.com/siebel-server-component-processes-shells/' rel='bookmark' title='Permanent Link: Siebel Server Component Processes (Shells)'>Siebel Server Component Processes (Shells)</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/hung-processes-in-siebel-servers/feed/</wfw:commentRss>
		<slash:comments>6</slash:comments>
		</item>
		<item>
		<title>How to EXTRACT SQL EXECUTION LOGS for specific User</title>
		<link>http://www.siebeloracle.com/steps-to-extract-sql-execution-logs-for-specific-user-id-siebel/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/steps-to-extract-sql-execution-logs-for-specific-user-id-siebel/#comments</comments>
		<pubDate>Mon, 08 Aug 2011 08:08:35 +0000</pubDate>
		<dc:creator>Sourav Mukherjee</dc:creator>
				<category><![CDATA[Server Administration]]></category>
		<category><![CDATA[Siebel Configuration]]></category>
		<category><![CDATA[Siebel Best Practice]]></category>
		<category><![CDATA[Siebel Server Administration]]></category>
		<category><![CDATA[Siebel Tips & Tricks]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=4996</guid>
		<description><![CDATA[In day to day life Siebel application developer has to deal with scenarios where few functionality or some configuration is making Siebel application latent. Developer has to extract the SQL queries to analyze the problematic functionality.&#160;We are sharing structured steps to analyze and extract the SQL queries which are leading to latency in Siebel application
*Note: If the SQL execution Time for a SQL query is greater than 10 seconds for the SQL statements generated at the time of navigation in CRM application,then it means that there is possibility of Latency. ...


Related posts:<ol><li><a href='http://www.siebeloracle.com/how-to-capture-the-ecommunications-logs-for-specific-users-in-siebel/' rel='bookmark' title='Permanent Link: How to capture the eCommunications logs for specific users in Siebel'>How to capture the eCommunications logs for specific users in Siebel</a></li>
<li><a href='http://www.siebeloracle.com/how-to-capture-the-ecommunications-logs-for-specific-users-in-siebel-continued/' rel='bookmark' title='Permanent Link: How to capture the eCommunications logs for specific users in Siebel – Continued'>How to capture the eCommunications logs for specific users in Siebel – Continued</a></li>
<li><a href='http://www.siebeloracle.com/text-length-override-user-property-siebel/' rel='bookmark' title='Permanent Link: Text Length Override User Property'>Text Length Override User Property</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/steps-to-extract-sql-execution-logs-for-specific-user-id-siebel/feed/</wfw:commentRss>
		<slash:comments>6</slash:comments>
		</item>
		<item>
		<title>How to take Clean Bounce of Siebel Server</title>
		<link>http://www.siebeloracle.com/how-to-take-clean-bounce-of-siebel-server/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/how-to-take-clean-bounce-of-siebel-server/#comments</comments>
		<pubDate>Thu, 21 Jul 2011 09:19:38 +0000</pubDate>
		<dc:creator>Abhishek</dc:creator>
				<category><![CDATA[Server Administration]]></category>
		<category><![CDATA[Interview Question]]></category>
		<category><![CDATA[Siebel Eroor Codes]]></category>
		<category><![CDATA[Siebel Error]]></category>
		<category><![CDATA[Siebel Tips & Tricks]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=4959</guid>
		<description><![CDATA[In some cases Siebel servers not started after&#160;bounce and our investigation lead us to conclusion that&#160;clean bounce of Siebel Severs is must&#160;whenever below scenario is being faced:

Siebel Server is not starting up after bounce
Getting SISNAPI error for MQ components 
Multithreaded Components are not starting up after bounce

[Error Codes: SBL-GEN-00255, SBL-OSD-00220, SBL-OSD-02006, SBL-OSD-02011, SBL-OSD-00204, SBL-ADM-02049, SBL-GEN-00001]

What causes this problem?
&#160;Sometimes you can face the issue that Siebel Server threads fail when using start_server all.&#160;

On UNIX m/c there has been a scenario that Siebel server got shutdown without having run the stop_server script. ...


Related posts:<ol><li><a href='http://www.siebeloracle.com/siebel-server-not-shutting-down/' rel='bookmark' title='Permanent Link: Graceful Shutdown Of Siebel Server'>Graceful Shutdown Of Siebel Server</a></li>
<li><a href='http://www.siebeloracle.com/siebel-component-showing-unavailable/' rel='bookmark' title='Permanent Link: Siebel Component Showing UNAVAILABLE'>Siebel Component Showing UNAVAILABLE</a></li>
<li><a href='http://www.siebeloracle.com/synchronization-of-siebel-server-components/' rel='bookmark' title='Permanent Link: Synchronization Of  Siebel server components'>Synchronization Of  Siebel server components</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/how-to-take-clean-bounce-of-siebel-server/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Siebel Application Response Management (SARM)</title>
		<link>http://www.siebeloracle.com/sarm-siebel-application-response-management-files/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/sarm-siebel-application-response-management-files/#comments</comments>
		<pubDate>Mon, 18 Jul 2011 08:16:19 +0000</pubDate>
		<dc:creator>Sourav Mukherjee</dc:creator>
				<category><![CDATA[Server Administration]]></category>
		<category><![CDATA[Siebel Best Practice]]></category>
		<category><![CDATA[Siebel Server Administration]]></category>
		<category><![CDATA[Siebel Tips & Tricks]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=4919</guid>
		<description><![CDATA[Siebel Application Response Management (SARM) is a framework for identifying performance problems in the Siebel enterprise application. SARM allows administrators to collect critical performance and timing data, thereby making it possible to profile the execution of requests throughout the Siebel Server and its various components.
SARM files are also known as Sarmanlyzer files within the siebel servers. These Files are kept within&#160; siebel servers , contains the details about the &#8216;Response Time&#8217; of all the request&#160; flowing within the&#160; CRM application.
When enabled, Siebel ARM records and saves data in binary file ...


Related posts:<ol><li><a href='http://www.siebeloracle.com/how-to-capture-the-ecommunications-logs-for-specific-users-in-siebel/' rel='bookmark' title='Permanent Link: How to capture the eCommunications logs for specific users in Siebel'>How to capture the eCommunications logs for specific users in Siebel</a></li>
<li><a href='http://www.siebeloracle.com/performance-tuning-of-siebel-application/' rel='bookmark' title='Permanent Link: Performance Tuning of Siebel Application'>Performance Tuning of Siebel Application</a></li>
<li><a href='http://www.siebeloracle.com/steps-to-extract-sql-execution-logs-for-specific-user-id-siebel/' rel='bookmark' title='Permanent Link: How to EXTRACT SQL EXECUTION LOGS for specific User'>How to EXTRACT SQL EXECUTION LOGS for specific User</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/sarm-siebel-application-response-management-files/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Siebel Server Component Processes (Shells)</title>
		<link>http://www.siebeloracle.com/siebel-server-component-processes-shells/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/siebel-server-component-processes-shells/#comments</comments>
		<pubDate>Wed, 06 Jul 2011 04:29:58 +0000</pubDate>
		<dc:creator>Abhishek</dc:creator>
				<category><![CDATA[Server Administration]]></category>
		<category><![CDATA[Siebel Interview Question Answer]]></category>
		<category><![CDATA[Siebel Server Administration]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=4884</guid>
		<description><![CDATA[The Siebel Server runs each component in its own separate process (or shell). These shells provide interface for a component to communicate with shared memory, and use infrastructure facilities for logging, events, networking, and so on. A shell performs the following actions when it is forked off:
&#160;




&#216;&#160; Initializes the logging and networking facility.
&#160;
&#216;&#160; Determines which component to run. The component is specified as a DLL (personality DLL), which is run by the Siebel Server either as part of the input parameters or as part of a network message.&#160;

&#160;



&#216;&#160; Attaches to ...


Related posts:<ol><li><a href='http://www.siebeloracle.com/siebel-enterprise-server-an-overview/' rel='bookmark' title='Permanent Link: Siebel Enterprise Server &#8211; An Overview'>Siebel Enterprise Server &#8211; An Overview</a></li>
<li><a href='http://www.siebeloracle.com/hung-processes-in-siebel-servers/' rel='bookmark' title='Permanent Link: HUNG PROCESSES In Siebel Servers'>HUNG PROCESSES In Siebel Servers</a></li>
<li><a href='http://www.siebeloracle.com/siebel-component-showing-unavailable/' rel='bookmark' title='Permanent Link: Siebel Component Showing UNAVAILABLE'>Siebel Component Showing UNAVAILABLE</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/siebel-server-component-processes-shells/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Siebel Component Showing UNAVAILABLE</title>
		<link>http://www.siebeloracle.com/siebel-component-showing-unavailable/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/siebel-component-showing-unavailable/#comments</comments>
		<pubDate>Wed, 15 Jun 2011 06:13:55 +0000</pubDate>
		<dc:creator>Rajiv Meruva</dc:creator>
				<category><![CDATA[Server Administration]]></category>
		<category><![CDATA[Siebel Eroor Codes]]></category>
		<category><![CDATA[Siebel Server Administration]]></category>
		<category><![CDATA[Siebel Tips]]></category>
		<category><![CDATA[Siebel Tips & Tricks]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=4853</guid>
		<description><![CDATA[We&#160;faced a strange situation as&#160;components were not taking any request and component were going to&#160;&#8220;UNAVAILABLE&#8221; state. This should not happen especially for the *Application Object Manager Components.
*Note: The number defined in MinMTServer **&#160;of the component decides how many processes will be started when the component will start.Component is in unavailable state means that application server&#160;is running but no precess is running for the component.
Possible causes:
We have file called Siebns.dat which use to keep the complete enterprise information. 
&#183;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160; Whenever we increase the log level for Object Manager to 4 or ...


Related posts:<ol><li><a href='http://www.siebeloracle.com/cancel-long-running-query-in-siebel-ui-cancelquerytimeout/' rel='bookmark' title='Permanent Link: Cancel Long Running Query In UI || CancelQueryTimeOut'>Cancel Long Running Query In UI || CancelQueryTimeOut</a></li>
<li><a href='http://www.siebeloracle.com/siebel-file-system-and-file-system-manager/' rel='bookmark' title='Permanent Link: Siebel File System and File System Manager'>Siebel File System and File System Manager</a></li>
<li><a href='http://www.siebeloracle.com/how-to-take-clean-bounce-of-siebel-server/' rel='bookmark' title='Permanent Link: How to take Clean Bounce of Siebel Server'>How to take Clean Bounce of Siebel Server</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/siebel-component-showing-unavailable/feed/</wfw:commentRss>
		<slash:comments>4</slash:comments>
		</item>
		<item>
		<title>Decode Siebel Error Codes</title>
		<link>http://www.siebeloracle.com/decode-siebel-error-codes/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/decode-siebel-error-codes/#comments</comments>
		<pubDate>Fri, 03 Jun 2011 09:46:14 +0000</pubDate>
		<dc:creator>Ashish Kr. Bameta</dc:creator>
				<category><![CDATA[Server Administration]]></category>
		<category><![CDATA[Siebel Architecture]]></category>
		<category><![CDATA[Siebel Configuration]]></category>
		<category><![CDATA[Siebel EAI]]></category>
		<category><![CDATA[Siebel EIM]]></category>
		<category><![CDATA[Siebel ERROR]]></category>
		<category><![CDATA[Siebel Pricing]]></category>
		<category><![CDATA[Siebel Scripting]]></category>
		<category><![CDATA[WorkFlow Policy]]></category>
		<category><![CDATA[WorkFlow Process]]></category>
		<category><![CDATA[Siebel Eroor Codes]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=4783</guid>
		<description><![CDATA[Siebel Error Codes are most challenging barriers for a developer. It&#8217;s very difficult to understand the exact problem in configuration by seeing the error codes. Consultant spent their important time in searching at number of blogs and oracle metalink support to find the correct explanation of the Siebel Error Codes. We are providing you a library of all siebel error codes to make your search efficient.
You are open to provide updated information and share Siebel Error Codes which are not the part of our knowledgebase.
Happy Debugging !!!!!!!!!!!!! 

&#160;Siebel Error Codes:
SBL-EAI-05010: ...


Related posts:<ol><li><a href='http://www.siebeloracle.com/steps-to-fix-siebel-error-for-siebel-pricing-product-configurator/' rel='bookmark' title='Permanent Link: Fix For Siebel Error Of Siebel Pricing &#8211; Product Configurator'>Fix For Siebel Error Of Siebel Pricing &#8211; Product Configurator</a></li>
<li><a href='http://www.siebeloracle.com/implementation-of-an-error-control-in-a-workflow-in-siebel/' rel='bookmark' title='Permanent Link: Implementation Of Error Control In A Workflow'>Implementation Of Error Control In A Workflow</a></li>
<li><a href='http://www.siebeloracle.com/error-loading-attachments-using-siebel-eim/' rel='bookmark' title='Permanent Link: Error – Loading attachments using Siebel EIM'>Error – Loading attachments using Siebel EIM</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/decode-siebel-error-codes/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>How to capture the eCommunications logs for specific users in Siebel – Continued</title>
		<link>http://www.siebeloracle.com/how-to-capture-the-ecommunications-logs-for-specific-users-in-siebel-continued/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/how-to-capture-the-ecommunications-logs-for-specific-users-in-siebel-continued/#comments</comments>
		<pubDate>Mon, 14 Feb 2011 04:08:20 +0000</pubDate>
		<dc:creator>Rajiv Meruva</dc:creator>
				<category><![CDATA[Interview Question]]></category>
		<category><![CDATA[Server Administration]]></category>
		<category><![CDATA[Siebel Knowledge]]></category>
		<category><![CDATA[Siebel Best Practice]]></category>
		<category><![CDATA[Siebel Tips & Tricks]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=4506</guid>
		<description><![CDATA[In last article &#34;How to capture the eCommunications logs for specific users in Siebel&#34; we have learned How to set user list and log levels.&#160; This article will help us in finding logs for any specific user.
&#160;

Finding&#160;the logs for the specific users
If there are multiple users accessing the same application then it will be difficult to find out the logs for the specific users. To solve this problem we have table called S_SRM_TASK_HIST where all the task details of a component will be stored. The details like server host name, ...


Related posts:<ol><li><a href='http://www.siebeloracle.com/how-to-capture-the-ecommunications-logs-for-specific-users-in-siebel/' rel='bookmark' title='Permanent Link: How to capture the eCommunications logs for specific users in Siebel'>How to capture the eCommunications logs for specific users in Siebel</a></li>
<li><a href='http://www.siebeloracle.com/steps-to-extract-sql-execution-logs-for-specific-user-id-siebel/' rel='bookmark' title='Permanent Link: How to EXTRACT SQL EXECUTION LOGS for specific User'>How to EXTRACT SQL EXECUTION LOGS for specific User</a></li>
<li><a href='http://www.siebeloracle.com/automatation-of-actuate-synchronization-for-new-siebel-users/' rel='bookmark' title='Permanent Link: Automatation of Actuate Synchronization for New Siebel Users'>Automatation of Actuate Synchronization for New Siebel Users</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/how-to-capture-the-ecommunications-logs-for-specific-users-in-siebel-continued/feed/</wfw:commentRss>
		<slash:comments>3</slash:comments>
		</item>
		<item>
		<title>How to capture the eCommunications logs for specific users in Siebel</title>
		<link>http://www.siebeloracle.com/how-to-capture-the-ecommunications-logs-for-specific-users-in-siebel/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/how-to-capture-the-ecommunications-logs-for-specific-users-in-siebel/#comments</comments>
		<pubDate>Thu, 10 Feb 2011 03:46:25 +0000</pubDate>
		<dc:creator>Rajiv Meruva</dc:creator>
				<category><![CDATA[Interview Question]]></category>
		<category><![CDATA[Server Administration]]></category>
		<category><![CDATA[Siebel Knowledge]]></category>
		<category><![CDATA[Siebel Tips & Tricks]]></category>
		<category><![CDATA[Siebel Best Practice]]></category>
		<category><![CDATA[Siebel Interview Question Answer]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=4471</guid>
		<description><![CDATA[Steps to set high level logs of Object manager for specific users&#160;to troubleshoot siebel performance issue.It is necessary to capture the high level logs to identify the root cause. It will help us to monitor the application performance by capturing the high level logs. We can identify the SQL quires which are causing latency as well as the flow of commands in OM&#160;.&#160;If we increase the log level for the most essential component like object manager it will effect to the performance of the application. To overcome this we can ...


Related posts:<ol><li><a href='http://www.siebeloracle.com/how-to-capture-the-ecommunications-logs-for-specific-users-in-siebel-continued/' rel='bookmark' title='Permanent Link: How to capture the eCommunications logs for specific users in Siebel – Continued'>How to capture the eCommunications logs for specific users in Siebel – Continued</a></li>
<li><a href='http://www.siebeloracle.com/steps-to-extract-sql-execution-logs-for-specific-user-id-siebel/' rel='bookmark' title='Permanent Link: How to EXTRACT SQL EXECUTION LOGS for specific User'>How to EXTRACT SQL EXECUTION LOGS for specific User</a></li>
<li><a href='http://www.siebeloracle.com/how-to-find-no-of-active-users-in-siebel-application/' rel='bookmark' title='Permanent Link: Finding active users in Siebel'>Finding active users in Siebel</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/how-to-capture-the-ecommunications-logs-for-specific-users-in-siebel/feed/</wfw:commentRss>
		<slash:comments>3</slash:comments>
		</item>
		<item>
		<title>Cancel Long Running Query In UI &#124;&#124; CancelQueryTimeOut</title>
		<link>http://www.siebeloracle.com/cancel-long-running-query-in-siebel-ui-cancelquerytimeout/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/cancel-long-running-query-in-siebel-ui-cancelquerytimeout/#comments</comments>
		<pubDate>Sun, 06 Feb 2011 16:53:33 +0000</pubDate>
		<dc:creator>Ashish Kr. Bameta</dc:creator>
				<category><![CDATA[Server Administration]]></category>
		<category><![CDATA[Siebel Tips & Tricks]]></category>
		<category><![CDATA[Siebel Server Administration]]></category>
		<category><![CDATA[Siebel Tips]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=4569</guid>
		<description><![CDATA[Control Long running queries by getting cancel button pop up after a set time period for great UI experience.
Siebel UI gets hang due to long running queries and if user closes the browser an orphan task is left in object manager. The functionality of canceling the query from UI is highly appreciated for great user UI experience. We can set a time and if query is running after that set time a pop-up window with cancel button will appear&#160;to help user to stop the query.
This parameter is called &#34;CancelQueryTimeOut parameter&#34; ...


Related posts:<ol><li><a href='http://www.siebeloracle.com/e-mail-not-working-siebel-work-flow-policy/' rel='bookmark' title='Permanent Link: E-mail not working in Siebel'>E-mail not working in Siebel</a></li>
<li><a href='http://www.siebeloracle.com/siebel-component-showing-unavailable/' rel='bookmark' title='Permanent Link: Siebel Component Showing UNAVAILABLE'>Siebel Component Showing UNAVAILABLE</a></li>
<li><a href='http://www.siebeloracle.com/synchronization-of-siebel-server-components/' rel='bookmark' title='Permanent Link: Synchronization Of  Siebel server components'>Synchronization Of  Siebel server components</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/cancel-long-running-query-in-siebel-ui-cancelquerytimeout/feed/</wfw:commentRss>
		<slash:comments>3</slash:comments>
		</item>
		<item>
		<title>Administration – Server Configuration Activities – Continued</title>
		<link>http://www.siebeloracle.com/adminisiebel-server-configuration-activities-continued/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/adminisiebel-server-configuration-activities-continued/#comments</comments>
		<pubDate>Wed, 02 Feb 2011 04:03:16 +0000</pubDate>
		<dc:creator>Ashish Kr. Bameta</dc:creator>
				<category><![CDATA[An Overview]]></category>
		<category><![CDATA[Interview Question]]></category>
		<category><![CDATA[Server Administration]]></category>
		<category><![CDATA[Siebel Server Administration]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=4530</guid>
		<description><![CDATA[In last article we have discussed about various siebel server configuration activities in Administration &#8211; Server Configuration screen.&#160; Let&#39;s know more about&#160;below activities.
&#8226;Use component alerts&#160;&#160;&#8226;Create and define job templates&#160; &#8226;Back up and restore enterprise configuration 

Use Component Alerts
&#8226; Traps information about the failure of tasks and unavailability of components and sends an email alert to the Administrator
&#8226; Examples: &#60;&#62; A component fails to restart &#60;&#62; Critical system throughput thresholds are hit &#8226; Additional alerts and parameters can be set up
&#160;

Create and Define Job Templates
&#8226; Create and define job templates for ...


Related posts:<ol><li><a href='http://www.siebeloracle.com/siebel-administration-server-configuration-activities/' rel='bookmark' title='Permanent Link: Administration &#8211; Server Configuration Activities'>Administration &#8211; Server Configuration Activities</a></li>
<li><a href='http://www.siebeloracle.com/siebel-recommended-practices-server-administration/' rel='bookmark' title='Permanent Link: Siebel Recommended Practices &#8211; Server Administration'>Siebel Recommended Practices &#8211; Server Administration</a></li>
<li><a href='http://www.siebeloracle.com/siebel-enterprise-server-an-overview/' rel='bookmark' title='Permanent Link: Siebel Enterprise Server &#8211; An Overview'>Siebel Enterprise Server &#8211; An Overview</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/adminisiebel-server-configuration-activities-continued/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Administration &#8211; Server Configuration Activities</title>
		<link>http://www.siebeloracle.com/siebel-administration-server-configuration-activities/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/siebel-administration-server-configuration-activities/#comments</comments>
		<pubDate>Mon, 31 Jan 2011 03:41:56 +0000</pubDate>
		<dc:creator>Ashish Kr. Bameta</dc:creator>
				<category><![CDATA[Interview Question]]></category>
		<category><![CDATA[Server Administration]]></category>
		<category><![CDATA[An Overview]]></category>
		<category><![CDATA[Siebel Server Administration]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=1477</guid>
		<description><![CDATA[In this series of article we are going to discuss about siebel server configuration activities under following categories.

This article will discuss&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160; &#8226;Define component definitions&#160;&#160;&#160;&#8226;Reconfigure component definition&#160; 
&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160; &#8226;Synchronize component&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#160;&#8226;Set server and component event logging

&#160;Define Component Definitions
&#8226; Tailor existing components or create custom components using these steps:

&#160;
Reconfigure Component Definitions
&#8226; Is accomplished through the Component Definitions applet drop-down menu
&#8226; Start Reconfiguration: Opens existing component parameters for modification
&#8226; Commit Reconfiguration: Commits the updated Component Definition
&#8226; Cancel Reconfiguration: Cancels the current reconfiguration, component definition remains unaltered




Synchronize Components
&#8226; A required post-installation task for executing components ...


Related posts:<ol><li><a href='http://www.siebeloracle.com/adminisiebel-server-configuration-activities-continued/' rel='bookmark' title='Permanent Link: Administration – Server Configuration Activities – Continued'>Administration – Server Configuration Activities – Continued</a></li>
<li><a href='http://www.siebeloracle.com/siebel-eim-tasks-log-unable-to-trace-the-sql/' rel='bookmark' title='Permanent Link: EIM tasks log unable to trace the SQL'>EIM tasks log unable to trace the SQL</a></li>
<li><a href='http://www.siebeloracle.com/siebel-recommended-practices-server-administration/' rel='bookmark' title='Permanent Link: Siebel Recommended Practices &#8211; Server Administration'>Siebel Recommended Practices &#8211; Server Administration</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/siebel-administration-server-configuration-activities/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Siebel Recommended Practices &#8211; Server Administration</title>
		<link>http://www.siebeloracle.com/siebel-recommended-practices-server-administration/#utm_source=feed&#038;utm_medium=feed&#038;utm_campaign=feed</link>
		<comments>http://www.siebeloracle.com/siebel-recommended-practices-server-administration/#comments</comments>
		<pubDate>Tue, 17 Nov 2009 19:12:09 +0000</pubDate>
		<dc:creator>Narsimha Dandala</dc:creator>
				<category><![CDATA[Server Administration]]></category>
		<category><![CDATA[Siebel Best Practice]]></category>

		<guid isPermaLink="false">http://www.siebeloracle.com/?p=2400</guid>
		<description><![CDATA[I am sharing few best practices for Server Administration, These are well practiced and used. Please leave a comment if  any clarification or further discussion required.
1. The recommended method for revising the lbconfig.txt file is to regenerate it.
2. It is recommended that you make a backup of the Siebel Gateway Name Server data—which contains configuration information from the Enterprise and Siebel Servers—prior to and after making any configuration changes, especially creating new component definitions and adding or deleting Siebel Servers. The Siebel Gateway Name Server information is stored in the siebns.dat file located in ...


Related posts:<ol><li><a href='http://www.siebeloracle.com/adminisiebel-server-configuration-activities-continued/' rel='bookmark' title='Permanent Link: Administration – Server Configuration Activities – Continued'>Administration – Server Configuration Activities – Continued</a></li>
<li><a href='http://www.siebeloracle.com/siebel-administration-server-configuration-activities/' rel='bookmark' title='Permanent Link: Administration &#8211; Server Configuration Activities'>Administration &#8211; Server Configuration Activities</a></li>
<li><a href='http://www.siebeloracle.com/siebel-architecture-siebel-server/' rel='bookmark' title='Permanent Link: Siebel Architecture and Servers &#8211; An Overview'>Siebel Architecture and Servers &#8211; An Overview</a></li>
</ol>]]></description>
		<wfw:commentRss>http://www.siebeloracle.com/siebel-recommended-practices-server-administration/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

